Product Finder

Items 1-10 of 178

Page
per page
Set Descending Direction
  1. ATS 400 Bild 1
    ATS400 UHIR-5030L
    Article number 211375
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA, potential free, ramp, discharge monitoring
    • ISO - Insulation Testing
      50,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • R - Resistance Measurement DC4
      1 µA - 2 A, 0,01 µΩ - 2,2000 MΩ, 4-wire measuring technique, contact monitoring, automatic measuring range selection, optional 11 fixed measuring ranges
    • Contacting options
      CCC
  2. ATS 400 Bild 1
    ATS400 UH-50
    Article number 202036
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 100,00 mA (opt. from 1 nA), potential free, ramp, discharge monitoring
    • Contacting options
      CC
  3. ATS 400 Bild 1
    ATS400 UH-50L
    Article number 207093
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,01 - 2,50 mA (opt. from 1 nA), current limited, potential free, ramp, discharge monitoring
    • Contacting options
      CC
  4. ATS 400 Bild 1
    ATS400 UGI-36L36L, current limited
    Article number 206229
    • HV DC - High Voltage Testing
      150,0 - 5000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring
    • Contacting options
      CC
  5. ATS 400 Bild 1
    ATS400 UG-70
    Article number 202035
    • HV DC - High Voltage Testing
      150,0 - 7000 V DC, 0,01 - 100,00 mA (opt. from 1 nA), max. 500VA, potential free, ramp, discharge monitoring
    • Contacting options
      CC
  6. ATS 400 Bild 1
    ATS400 I-10L-1G
    Article number 206698
    • ISO - Insulation Testing
      50,0 - 1000 V DC, 500,0 kΩ - 1000 MΩ (opt. 5 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • Contacting options
      CC
  7. ATS 400 Bild 1
    ATS400 I-30L-1G
    Article number 205712
    • ISO - Insulation Testing
      50,0 - 3000 V DC, 500,0 kΩ - 1000 MΩ (opt. 10 GΩ), current limited accor. EN 50191, earthed on one side, active discharge, ramp, discharge monitoring
    • Contacting options
      CC
  8. Hi Pot Tester UH36 - 5 kV AC / 100 mA / 500 VA
    Hi Pot Tester UH36 - 5 kV AC / 100 mA / 500 VA
    Article number 200208
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,50 - 100 mA , potential free, ramp, discharge monitoring
  9. Hi Pot Tester UB36 - 5kV AC / 2,5 mA / current-limited
    Hi Pot Tester UB36 - 5kV AC / 2,5 mA / current-limited
    Article number 201788
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,5 - 2,5 mA, current limited, potential free, ramp, discharge monitoring
  10. Hi Pot Tester UG36 - 6 kV DC / 10 mA / current-limited
    Hi Pot Tester UG36 - 6 kV DC / 10 mA / current-limited
    Article number 201866
    • HV DC - High Voltage Testing
      100,0 - 6000 V DC, 0,1 - 10 mA, current limited, potential free, ramp, discharge monitoring

Items 1-10 of 178

Page
per page
Set Descending Direction