36 Series | Single Testers

Single testers that can do more

Series 36 specialises in individual testing tasks and is therefore ideal for cost-conscious customers who need to perform either a high-voltage test or a protective conductor test (PE test). It comprises four different standard test devices and various special test devices for customised requirements. A wide range of test voltages and test currents (up to 100 kV) can be covered.

Serie 36
  •   Simple usability
  •   Robust and long-lasting
  •   Easy maintenance
  •   Cost benefits through reduction to the essentials
  •   Voltage and current can be customised (for UX36)
Series 36 - Standard test devices

Our handy Series 36 standard testers with their robust design are ideal for high-voltage tests up to 6 kV and 100 mA and protective conductor tests up to 25 A. We offer four different versions: HV-DC testers (UG36), HV-AC testers (UH36), HV-AC current-limited single testers (UB36) and PE devices (RS36).

Serie 36 family
UX special test devices - Series 36 in a special guise

The UX special test devices are the ideal solution for customers who need to test with high voltages or high currents (up to 100 kV). The test variables can be selected according to customer requirements. These test systems are particularly suitable for special applications such as testing trains or for electrical testing of wind turbines. The big advantage for you: in addition to classic desktop units, we also offer mobile solutions on test carts, which means that the test is practically delivered to the test object.

UX zweiteiliger Prüfplatz
 

More about Series 36:

Features

Shut-down over limit detection and peak detection
Insulation fault of the test object can be detected by several criteria. Insulation fault alarm will be triggered by a current over limit exceedance or by a special peak detection in order to detect even low-energy spikes.

Voltage ramp and detection of disruptive discharge voltage
The voltage ramp can be switched on in addition. Parameters like rise time and fall time are freely selectable. The voltage ramp enables safe testing and it is absolutely necessary for testing to norms which require special voltage curves. The voltage at which an isolation fault is detected, will be permanently displayed as a flashing value.

Key panel interlock
The key panel interlock prevents incorrect setting of parameters. It can be set up individually. For example all pushbuttons may be locked. Also desired functions can be left unlocked.

Test device for operating “Stand-Alone” or remotely controlled via interface
The test device can be controlled by a Windows software (user interface software DataView), by a self created custom software application (DLL, C#, .NET, LabView), simple command parameters (ASCII) or digitally with a PLC (Digital-IO).

Automatic start up
The start signal can be triggered by slightly pressing the test pistols to the test object. The test voltage will only be switched-on when the tips of both test pistols are safely connected to the test object. This will prevent the test object from voltage peaks and ensures the correct test time.

Cable break monitoring and connection monitoring to the test object
The high voltage cables are designed for 4-wire technology. Source-sense monitoring ensures maximum process reliability (patent).

Freely programmable sets of parameters
15 freely programmable sets of parameters are available for recalling test parameters.

Signalling: Acoustic, optical and communication interface
Faulty test objects can be reliably identified. Indication lights will also flash additionally.

Safety circuit including two forcibly guided safety relays
The safety technology is designed according to EN 50191.

Measuring of current and voltage directly on the high voltage section
Direct measurement guarantees absolute accurate test results.

Regulated test voltage
Continously PI-controlled (power integral) test voltage is stabilized regardless of fluctuations in the mains voltage.

High voltage, potential-free
The test voltage is potential-free. This grants highest possible security for the operating person and this is a requirement for performing high voltage tests by using test pistols.

Individual setup
Start options, language, behaviour of digital IO interface, voltage ramp options, options for connection and cable break monitoring, etc.

Updatable via interface
For customer specific adaptions and updates.

Downloads

Items 1-10 of 18

Page
per page
Set Descending Direction
  1. Hi Pot Tester UH36 - 5 kV AC / 100 mA / 500 VA
    Hi Pot Tester UH36 - 5 kV AC / 100 mA / 500 VA
    Article number 200208
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,50 - 100 mA , potential free, ramp, discharge monitoring
  2. Two-part test system ZPA - 35 kV / 120 mA / 4200 VA with oil transformer
    Two-part test system ZPA - 35 kV / 120 mA / 4200 VA with oil transformer
    Article number 207250
    • HV AC - High Voltage Testing
      1000 - 35000 V AC, 0,5, - 120 mA, ramp
  3. Two-part test system ZPA - 75 kV AC / 100 mA / 7500 VA with oil transformer
    Two-part test system ZPA - 75 kV AC / 100 mA / 7500 VA with oil transformer
    Article number 203086
    • HV AC - High Voltage Testing
      1000 - 75000 V AC, 0,50 - 100 mA , ramp
  4. Two-part test system ZPA - 35 kV AC / 200 mA / 7000 VA with oil transfomer
    Two-part test system ZPA - 35 kV AC / 200 mA / 7000 VA with oil transfomer
    Article number 203242
    • HV AC - High Voltage Testing
      1000 - 35000 V AC, 0,50 - 200 mA, ramp
  5. Two-part test system ZPA - 60 kV / 300 mA / 18000 VA with oil transformer
    Two-part test system ZPA - 60 kV / 300 mA / 18000 VA with oil transformer
    Article number 207023
    • HV AC - High Voltage Testing
      1000 - 60000 V AC, 0,50 - 300 mA, ramp
  6. Hi Pot Tester UX36 - 6 kV AC / 200 mA / 1200 VA with dry transformer
    Hi Pot Tester UX36 - 6 kV AC / 200 mA / 1200 VA with dry transformer
    Article number 202351
    • HV AC - High Voltage Testing
      100,0 - 6000 V AC, 0,50 - 200 mA, potential free, ramp
  7. Hi Pot Tester UX36 - 12 kV AC / 200 mA / 2400 VA with dry transformer
    Hi Pot Tester UX36 - 12 kV AC / 200 mA / 2400 VA with dry transformer
    Article number 205688
    • HV AC - High Voltage Testing
      500,0 - 12000 V AC, 0,50 - 200 mA, potential free, ramp
  8. Hi Pot Tester UX36 - 5 kV AC / 500 mA / 2500 VA with dry transformer
    Hi Pot Tester UX36 - 5 kV AC / 500 mA / 2500 VA with dry transformer
    Article number 204114
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 1,00 - 500 mA, potential free, ramp
  9. Hi Pot Tester UX36 - 5 kV AC / 200 mA / 1000 VA with dry transformer
    Hi Pot Tester UX36 - 5 kV AC / 200 mA / 1000 VA with dry transformer
    Article number 202194
    • HV AC - High Voltage Testing
      100,0 - 5000 V AC, 0,50 - 200 mA, potential free, ramp
  10. Hi Pot Tester UX36 - 12 kV AC / 100 mA, 16 kV / 70 mA / 1200 VA
    Hi Pot Tester UX36 - 12 kV AC / 100 mA, 16 kV / 70 mA / 1200 VA
    Article number 206465
    • HV AC - High Voltage Testing
      500,0 - 12000 V AC, 0,50 - 100 mA , potential free, ramp
    • HV DC - High Voltage Testing
      500 - 16000 V DC, 0,50 - 70,0 mA, potential free, ramp

Items 1-10 of 18